Trial Outcomes & Findings for Study on ASTRA TECH Implant System, OsseoSpeed™ Implants in Patients Missing All Teeth in the Upper Jaw, Restored With Provisional Teeth Within 24 Hours (NCT NCT00711022)
NCT ID: NCT00711022
Last Updated: 2014-07-16
Results Overview
An implant that has failed to osseointegrate, lost its osseointegration or fractured was considered a failure effective from the date of removal. The survival rate for individual implants was analyzed at each visit. Cumulative implant survival rate was calculated using Kaplan-Meier life-table estimation and reported as percentage of survived implants.
COMPLETED
NA
51 participants
At 5-year follow-up
2014-07-16
Participant Flow
Participant milestones
| Measure |
OsseoSpeed
ASTRA TECH Implant System, OsseoSpeed™, all dimensions.
|
|---|---|
|
Overall Study
STARTED
|
51
|
|
Overall Study
COMPLETED
|
40
|
|
Overall Study
NOT COMPLETED
|
11
|
Reasons for withdrawal
Withdrawal data not reported
Baseline Characteristics
Study on ASTRA TECH Implant System, OsseoSpeed™ Implants in Patients Missing All Teeth in the Upper Jaw, Restored With Provisional Teeth Within 24 Hours
Baseline characteristics by cohort
| Measure |
OsseoSpeed
n=51 Participants
ASTRA TECH Implant System, OsseoSpeed™, all dimensions.
|
|---|---|
|
Age, Continuous
|
65.8 years
STANDARD_DEVIATION 10 • n=5 Participants
|
|
Sex: Female, Male
Female
|
27 Participants
n=5 Participants
|
|
Sex: Female, Male
Male
|
24 Participants
n=5 Participants
|
PRIMARY outcome
Timeframe: At 5-year follow-upPopulation: Per protocol analysis presented, this includes implants loaded within 24 hours from implant placement (306 implants in 51 subjects), of these 20 implants failed during the 5 year follow-up period.
An implant that has failed to osseointegrate, lost its osseointegration or fractured was considered a failure effective from the date of removal. The survival rate for individual implants was analyzed at each visit. Cumulative implant survival rate was calculated using Kaplan-Meier life-table estimation and reported as percentage of survived implants.
Outcome measures
| Measure |
OsseoSpeed
n=306 Implants
ASTRA TECH Implant System, OsseoSpeed™, all dimensions.
|
|---|---|
|
Implant Survival Rate
|
93.10 percentage of implants
|
Adverse Events
OsseoSpeed
Serious adverse events
| Measure |
OsseoSpeed
n=51 participants at risk
ASTRA TECH Implant System, OsseoSpeed™, all dimensions.
|
|---|---|
|
Gastrointestinal disorders
Obstructed small intestine
|
2.0%
1/51
|
|
Vascular disorders
Stroke
|
2.0%
1/51
|
|
Vascular disorders
Cerebral vascular accident
|
2.0%
1/51
|
|
Gastrointestinal disorders
Rectal issue
|
2.0%
1/51
|
|
General disorders
Drug related reaction
|
2.0%
1/51
|
Other adverse events
Adverse event data not reported
Additional Information
Senior Manager Global Clinical Research
DENTSPLY Implants
Results disclosure agreements
- Principal investigator is a sponsor employee
- Publication restrictions are in place
Restriction type: LTE60