Assessment of Hemodynamic Changes During Weaning From Mechanical Ventilation With Flo-Trac Vigileo (TM) Monitor.
NCT ID: NCT00631683
Last Updated: 2020-11-05
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
WITHDRAWN
OBSERVATIONAL
2008-02-29
2008-02-29
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
A new monitor (Vigileo TM) that is connected with a specific cable (Flo-TracTM) to a catheter that is inside the patient's artery (arterial line) has lately been developed. This monitor can estimate the amount of blood that the heart is pumping per minute, known as cardiac output. The heart is supposed to pump blood harder when a patient is being weaned from the breathing machine. With the above mentioned monitor, we hope to detect those patients whose hearts are weak and are not pumping as hard as they should.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Although respiratory system failure is the most common cause of weaning failure, occult cardiovascular insufficiency occurs very often in critically ill patients, and it can contribute to, or be the only cause of weaning failure in many patients (2). Recognition of cardiovascular origin of weaning failure is crucial since the use of vasodilators and/or diuretics may result in successful weaning (1).
Cardiovascular instability during liberation from mechanical ventilation was first described more than 30 years ago by Beach et al (3) in post-operative cardiac surgery patients. Since then, a few other studies have described the hemodynamic changes both in patients who underwent successful and unsuccessful weaning form mechanical ventilation (1,4,5,6,7). Lemaire et al. (4) emphasized the use of a pulmonary artery catheter as the "gold standard" to detect left ventricular dysfunction during spontaneous breathing trial (SBT). They reported a markedly increased in pulmonary artery occlusion pressure (PAOP) in patients who were suffering from COPD or heart failure who failed to wean from mechanical wentilation. Jubran et al. (5) reported an increase in PAOP, decreased mixed venous oxygen saturation (SvO2) and an increase in the oxygen extraction ratio in a group of patients who failed to wean from mechanical ventilation. In contrast, De Backer et al. (6) described an increase in cardiac index in a group of patients who were successfully weaned after cardiac surgery. A recently published study by Frazier et al. (7) corroborated previous data by comparing the hemodynamic changes between a group of patients who were successfully weaned and a group of patients who failed to wean from mechanical ventilation. The cardiac output and stroke volume were estimated by the differential Fick partial rebreathing technique, with carbon dioxide as the indicator substance. The group of patients who were successfully weaned had a statistical significant increase in both stroke volume and cardiac index, unlike the group that failed weaning.
The physiologic changes that explain the above mentioned findings in hemodynamic parameters during weaning are complex and not fully understood (1). It is well known that weaning can place an excessive burden on the heart and it can be considered a form of "exercise" (2). As studied by exercise physiologists, the increase in oxygen consumption during exercise in healthy individuals is matched both by an increase in cardiac output and oxygen extraction. In patients with overt heart failure, the increase in cardiac output is inadequate, and the predominant response constitutes and increase in oxygen extraction. Return to spontaneous breathing induces alteration in intrathoracic pressures that influence cardiovascular function, producing, among other changes, an increase in venous return. Other postulated physiologic changes include increase sympathetic tone, weaning-induced myocardial ischemia and increased ventricular interdependence (2).
The recognition of cardiac origin of weaning failure is of vital importance. Unfortunately, the clinical signs of patients who fail weaning because of acute heart failure (tachypnea, tachycardia, anxiety, etc) are often difficult to distinguish from signs of respiratory failure. Reliable bedside minimally invasive monitoring tools and tests need to be developed to help the clinician in identifying these patients and help titrate cardiovascular therapies during weaning trials. Currently, the list of such tools is short and the validity of each technique in different situations is unknown (2).
Cardiovascular dysfunction may be the missing piece in predicting weaning success. Cardiovascular monitoring can be useful in identifying and managing patients who fail to wean due to lack of cardiac reserve.
We propose the use of Flo-Trac/VigileoTM, a semi-invasive technique that estimates cardiac output from the arterial pressure waveform, as a tool for cardiac monitoring during the process of weaning from mechanical ventilation.
References:
1. Richard C and Teboul JL. Weaning failure from cardiovascular origin. Intensive Care Med 2005;31:1605-1607
2. Pinsky MR. Breathing as exercise. Intensive care Med 2000;26:1164-1166
3. Beach T, Millen E, Grenvik A. Hemodynamic response to discontinuation from mechanical ventilation. Crit Care med 1973;1:85-90
4. Lemaire F, Teboul JL, Cinotti L, Giotto G, Abrouk F, Steg G, Macquin-Mavier I and Zapol W. Acute left ventricular dysfunction during unsuccessful weaning from mechanical ventilation. Anesthesiology 1998;69:171-179
5. Jubran A, Mathru M, dries D and Tobin MJ. Continuous recordings from Mixed Venous Oxygen Saturation during Weaning from Mechanical Ventilation and the Ramifications Thereof. Am J Respir Crit Care Med 1998:158:1763-1769
6. De Backer D, El Haddad P, Preiser JC and Vincent JL. Hemodynamic responses to successful weaning from mechanical ventilation after cardiovascular surgery. Intensive Care Med 2000;26:1201-1206
7. Frazier SK et al. Hemodynamic changes during discontinuation of mechanical ventilation in medical intensive care unit patients. Am J Crit Care 2006;15:580-593
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
MICU-1
Mechanically ventilated patients who are about to start a weaning trial at the medical intensive care unit of Memorial Hermann Hospital.
No interventions assigned to this group
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Arterial line in place
* Normal sinus rhythm by electrocardiographic monitoring
* Mechanical ventilation for at least 24 hours
* Ventilation via oral or nasal endotracheal tube
* Patient meets the following weaning criteria before starting weaning protocol:
* PaO2/FiO2 ratio \>200
* FiO2 equal or less than 50%
* Positive end-expiratory pressure (PEEP) 5cm H20 or less
* Respiratory frequency/Tidal volume ratio less 105
* Respiratory rate \< 30 breaths/min
* Presence of cough and gag reflex
* 12 hours free from sedation (opioids/benzodiazepine)
* 2 hours free from sedation in case patient is on Propofol
* Systolic blood pressure above 90 mmHg and below 180 mmHg
* Heart rate below 130 beats/min
Exclusion Criteria
* Known neuromuscular disease
* Inotropic or vasopressor infusion
* Cardiac pacemaker
* Terminal condition
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Edwards Lifesciences
INDUSTRY
The University of Texas Health Science Center, Houston
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Roberto F Casal, MD
Role: PRINCIPAL_INVESTIGATOR
The University of Texas Health Science Center, Houston
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Memorial Hermann Hospital
Houston, Texas, United States
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
HSC-MS-07-0368
Identifier Type: -
Identifier Source: org_study_id