Cap-fitted Colonoscopy: a Randomized, Tandem Colonoscopy Study of Adenoma Miss Rates

NCT ID: NCT00577083

Last Updated: 2018-12-10

Study Results

Results available

Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.

View full results

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

100 participants

Study Classification

INTERVENTIONAL

Study Start Date

2006-11-30

Study Completion Date

2009-10-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This is a test in which a thin, black, flexible tube with a lighting system on the end is passed through the anus, into the rectum, in order to examine the large bowel or intestine, also called the colon. Colonoscopy is a very good test for examining the colon for polyps (warty growths that can turn into cancer), but it is not perfect. In fact, about 30% of polyps that are under 5 mm (about 1/5 of an inch) in size are missed during colonoscopy because they are hiding behind folds and bends in the colon. This research study is being done to determine if performing colonoscopy with a cap on the tip of the colonoscope will reduce the miss rate for polyps. A cap is a clear plastic hood that fits on the tip of the colonoscope and sticks out about 1/3 of an inch. During colonoscopy, the cap can be pressed against a fold or ridge in order to flatten it, so that the lining on the other side can be more easily seen. This may reduce the miss rate for colon polyps.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Patient will undergo tandem colonoscopy on the same day using propofol sedation. Patients will undergo one colonoscopy without the cap and a second colonoscopy with the cap on. We will endeavor to keep the total examination time equal between the groups and approximately six minutes. The order in which patients receive the two colonoscopies (i.e. cap or without cap first) will be randomized. Any polyps detected during the first colonoscopy will be removed during that procedure. During the withdrawal phase, the time for examination will be measured with a stopwatch, and the stopwatch will be stopped at any time a polyp is located and restarted when the polyp has been removed and retrieved. The stopwatch will also be stopped for suctioning fluid or washing debris from the colon surface. Any polyp detected and removed during the first colonoscopy will be counted as the detection for that procedure. During the second colonoscopy, all polyps will also be removed when detected. Any polyp identified and removed during the second procedure will be counted as a miss for the first procedure. All polyps will be sent separately for pathologic evaluation. The time required to remove and retrieve polyps with and without the cap on will be measured using a stopwatch as a secondary end point. The primary end point will be the miss rate for colonoscopy with the cap and colonoscopy without the cap.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Polyps

Keywords

Explore important study keywords that can help with search, categorization, and topic discovery.

miss rates

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

CROSSOVER

Primary Study Purpose

SCREENING

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Initial cap-fitted

Initial cap-fitted colonoscopy for the first insertion

Group Type EXPERIMENTAL

Cap-fitted colonoscopy

Intervention Type DEVICE

Subjects will be randomized to either initial cap-fitted colonoscopy or regular colonoscopy. Patients in the initial regular arm, will undergo cap-fitted colonoscopy for their second, tandem examination. Patients in the initial cap-fitted arm, will under undergo regular colonoscopy (without the cap) for their second, tandem examination.

Initial regular

Initial regular no cap on the end of the colonoscope for the first insertion

Group Type ACTIVE_COMPARATOR

Cap-fitted colonoscopy

Intervention Type DEVICE

Subjects will be randomized to either initial cap-fitted colonoscopy or regular colonoscopy. Patients in the initial regular arm, will undergo cap-fitted colonoscopy for their second, tandem examination. Patients in the initial cap-fitted arm, will under undergo regular colonoscopy (without the cap) for their second, tandem examination.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Cap-fitted colonoscopy

Subjects will be randomized to either initial cap-fitted colonoscopy or regular colonoscopy. Patients in the initial regular arm, will undergo cap-fitted colonoscopy for their second, tandem examination. Patients in the initial cap-fitted arm, will under undergo regular colonoscopy (without the cap) for their second, tandem examination.

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

cap-assisted colonoscopy colonoscopy with detachable hood

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* 50 years of age or older, undergoing scheduled colonoscopy and able to give informed consent.

Exclusion Criteria

* Previous surgical resection of the colon or rectum
* American Society of Anesthesiology class III or higher
* Inflammatory bowel disease
* Current use of anticoagulants.
Minimum Eligible Age

50 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Indiana University

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Douglas K Rex, MD

Role: PRINCIPAL_INVESTIGATOR

Indiana University School of Medicine

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Indiana University Medical Center

Indianapolis, Indiana, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

References

Explore related publications, articles, or registry entries linked to this study.

Hewett DG, Rex DK. Cap-fitted colonoscopy: a randomized, tandem colonoscopy study of adenoma miss rates. Gastrointest Endosc. 2010 Oct;72(4):775-81. doi: 10.1016/j.gie.2010.04.030. Epub 2010 Jun 25.

Reference Type DERIVED
PMID: 20579648 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

0501-30

Identifier Type: -

Identifier Source: org_study_id