Trial Outcomes & Findings for A Multicenter Randomized Trial Comparing IM Nails and Plate Fixation in Proximal Tibial Fractures (NCT NCT00429585)
NCT ID: NCT00429585
Last Updated: 2021-11-02
Results Overview
The European Quality of Life Five Dimension (EQ-5D) Survey will be used to measure the participants' quality of life. The EQ-5D measures the subjects' overall state, including 5 domains: mobility, self-care, usual activities, pain/discomfort and anxiety/depression. Each dimension has 5 levels: 1= no problems, 2= slight problems, 3=moderate problems, 4=severe problems and 5=extreme problems. The score is determined by a scale and grading systems that can range from 0.01 to 1.00. The lower the score the less quality of life problems.
COMPLETED
NA
108 participants
3 months
2021-11-02
Participant Flow
9 participants were enrolled but were not randomized. Of those 9, 6 were found ineligible after consent and 3 withdrew consent prior to randomization.
Participant milestones
| Measure |
Randomized Treatment - Nail
Randomized Treatment - Nail
reamed, interlocking intramedullary nail: Standard of care device for tibia fracture repair; Randomized Treatment - Nail
|
Randomized Treatment - Plate
Randomized Treatment - Plate
locking periarticular plate: Standard of care device for tibia fracture repair; Randomized Treatment - Plate
|
|---|---|---|
|
Overall Study
STARTED
|
52
|
47
|
|
Overall Study
COMPLETED
|
22
|
27
|
|
Overall Study
NOT COMPLETED
|
30
|
20
|
Reasons for withdrawal
| Measure |
Randomized Treatment - Nail
Randomized Treatment - Nail
reamed, interlocking intramedullary nail: Standard of care device for tibia fracture repair; Randomized Treatment - Nail
|
Randomized Treatment - Plate
Randomized Treatment - Plate
locking periarticular plate: Standard of care device for tibia fracture repair; Randomized Treatment - Plate
|
|---|---|---|
|
Overall Study
Death
|
1
|
0
|
|
Overall Study
Lost to Follow-up
|
27
|
20
|
|
Overall Study
Physician Decision
|
2
|
0
|
Baseline Characteristics
Race and Ethnicity were not collected from any participant.
Baseline characteristics by cohort
| Measure |
Randomized Treatment - Nail
n=52 Participants
Randomized Treatment - Nail
reamed, interlocking intramedullary nail: Standard of care device for tibia fracture repair; Randomized Treatment - Nail
|
Randomized Treatment - Plate
n=47 Participants
Randomized Treatment - Plate
locking periarticular plate: Standard of care device for tibia fracture repair; Randomized Treatment - Plate
|
Total
n=99 Participants
Total of all reporting groups
|
|---|---|---|---|
|
Age, Continuous
|
43 years
n=52 Participants
|
48 years
n=47 Participants
|
46 years
n=99 Participants
|
|
Sex: Female, Male
Female
|
12 Participants
n=52 Participants
|
11 Participants
n=47 Participants
|
23 Participants
n=99 Participants
|
|
Sex: Female, Male
Male
|
40 Participants
n=52 Participants
|
36 Participants
n=47 Participants
|
76 Participants
n=99 Participants
|
|
Race and Ethnicity Not Collected
|
—
|
—
|
0 Participants
Race and Ethnicity were not collected from any participant.
|
|
Region of Enrollment
United States
|
52 participants
n=52 Participants
|
47 participants
n=47 Participants
|
99 participants
n=99 Participants
|
PRIMARY outcome
Timeframe: 3 monthsThe European Quality of Life Five Dimension (EQ-5D) Survey will be used to measure the participants' quality of life. The EQ-5D measures the subjects' overall state, including 5 domains: mobility, self-care, usual activities, pain/discomfort and anxiety/depression. Each dimension has 5 levels: 1= no problems, 2= slight problems, 3=moderate problems, 4=severe problems and 5=extreme problems. The score is determined by a scale and grading systems that can range from 0.01 to 1.00. The lower the score the less quality of life problems.
Outcome measures
| Measure |
Randomized Treatment - Nail
n=46 Participants
Randomized Treatment - Nail
reamed, interlocking intramedullary nail: Standard of care device for tibia fracture repair; Randomized Treatment - Nail
|
Randomized Treatment - Plate
n=38 Participants
Randomized Treatment - Plate
locking periarticular plate: Standard of care device for tibia fracture repair; Randomized Treatment - Plate
|
|---|---|---|
|
Participants' Quality of Life at 3 Months
|
0.60 score on a scale
Standard Deviation 0.24
|
0.59 score on a scale
Standard Deviation 0.20
|
PRIMARY outcome
Timeframe: 6 monthsThe European Quality of Life Five Dimension (EQ-5D) Survey will be used to measure the participants' quality of life. The EQ-5D measures the subjects' overall state, including 5 domains: mobility, self-care, usual activities, pain/discomfort and anxiety/depression. Each dimension has 5 levels: 1= no problems, 2= slight problems, 3=moderate problems, 4=severe problems and 5=extreme problems. The score is determined by a scale and grading systems that can range from 0.01 to 1.00. The lower the score the less quality of life problems.
Outcome measures
| Measure |
Randomized Treatment - Nail
n=43 Participants
Randomized Treatment - Nail
reamed, interlocking intramedullary nail: Standard of care device for tibia fracture repair; Randomized Treatment - Nail
|
Randomized Treatment - Plate
n=38 Participants
Randomized Treatment - Plate
locking periarticular plate: Standard of care device for tibia fracture repair; Randomized Treatment - Plate
|
|---|---|---|
|
Participants' Quality of Life at 6 Months
|
0.65 score on a scale
Standard Deviation 0.19
|
0.72 score on a scale
Standard Deviation 0.20
|
PRIMARY outcome
Timeframe: 12 monthsThe European Quality of Life Five Dimension (EQ-5D) Survey will be used to measure the participants' quality of life. The EQ-5D measures the subjects' overall state, including 5 domains: mobility, self-care, usual activities, pain/discomfort and anxiety/depression. Each dimension has 5 levels: 1= no problems, 2= slight problems, 3=moderate problems, 4=severe problems and 5=extreme problems. The score is determined by a scale and grading systems that can range from 0.01 to 1.00. The higher the score the less quality of life problems.
Outcome measures
| Measure |
Randomized Treatment - Nail
n=22 Participants
Randomized Treatment - Nail
reamed, interlocking intramedullary nail: Standard of care device for tibia fracture repair; Randomized Treatment - Nail
|
Randomized Treatment - Plate
n=27 Participants
Randomized Treatment - Plate
locking periarticular plate: Standard of care device for tibia fracture repair; Randomized Treatment - Plate
|
|---|---|---|
|
Participants' Quality of Life at 12 Months
|
0.60 score on a scale
Standard Deviation .24
|
0.775 score on a scale
Standard Deviation 0.16
|
PRIMARY outcome
Timeframe: 3 monthsParticipant limitations and bother from the injury will be assessed using the Short Musculoskeletal Function Assessment (SMFA).This survey asks the subject 46 questions, they are broken up into 2 parts. Part 1 relates to the difficulty/limitations the subject has related to their injury. Part 2 is how much the subject is bothered by this injury. Subjects provide score on a scale of 1 (no difficulty/bother) to 5 (highly difficult/bothered). The scoring range is between 0-100. The lower the score the less injury related limitations and bother.
Outcome measures
| Measure |
Randomized Treatment - Nail
n=46 Participants
Randomized Treatment - Nail
reamed, interlocking intramedullary nail: Standard of care device for tibia fracture repair; Randomized Treatment - Nail
|
Randomized Treatment - Plate
n=38 Participants
Randomized Treatment - Plate
locking periarticular plate: Standard of care device for tibia fracture repair; Randomized Treatment - Plate
|
|---|---|---|
|
Injury Related Limitations and Concerns at 3 Months
|
40.25 score on a scale
Standard Deviation 19.74
|
40.11 score on a scale
Standard Deviation 16.28
|
PRIMARY outcome
Timeframe: 6 monthsParticipant limitations and bother from the injury will be assessed using the Short Musculoskeletal Function Assessment (SMFA).This survey asks the subject 46 questions, they are broken up into 2 parts. Part 1 relates to the difficulty/limitations the subject has related to their injury. Part 2 is how much the subject is bothered by this injury. Subjects provide score on a scale of 1 (no difficulty/bother) to 5 (highly difficult/bothered). The scoring range is between 0-100. The lower the score the less injury related limitations and bother.
Outcome measures
| Measure |
Randomized Treatment - Nail
n=43 Participants
Randomized Treatment - Nail
reamed, interlocking intramedullary nail: Standard of care device for tibia fracture repair; Randomized Treatment - Nail
|
Randomized Treatment - Plate
n=38 Participants
Randomized Treatment - Plate
locking periarticular plate: Standard of care device for tibia fracture repair; Randomized Treatment - Plate
|
|---|---|---|
|
Injury Related Limitations and Concerns at 6 Months
|
32.19 score on a scale
Standard Deviation 18.70
|
27.70 score on a scale
Standard Deviation 18.58
|
PRIMARY outcome
Timeframe: 12 month follow-upParticipant limitations and bother from the injury will be assessed using the Short Musculoskeletal Function Assessment (SMFA).This survey asks the subject 46 questions, they are broken up into 2 parts. Part 1 relates to the difficulty/limitations the subject has related to their injury. Part 2 is how much the subject is bothered by this injury. Subjects provide score on a scale of 1 (no difficulty/bother) to 5 (highly difficult/bothered). The scoring range is between 0-100. The lower the score the less difficulty and bother.
Outcome measures
| Measure |
Randomized Treatment - Nail
n=22 Participants
Randomized Treatment - Nail
reamed, interlocking intramedullary nail: Standard of care device for tibia fracture repair; Randomized Treatment - Nail
|
Randomized Treatment - Plate
n=27 Participants
Randomized Treatment - Plate
locking periarticular plate: Standard of care device for tibia fracture repair; Randomized Treatment - Plate
|
|---|---|---|
|
Injury Related Limitations and Concerns at 12 Months
|
34.20 score on a scale
Standard Deviation 20.93
|
23.51 score on a scale
Standard Deviation 19.35
|
SECONDARY outcome
Timeframe: 12 monthsA nonunion is when a broken bone fails to heal. This is determined by a review of the participants' medical records and x-rays.
Outcome measures
| Measure |
Randomized Treatment - Nail
n=22 Participants
Randomized Treatment - Nail
reamed, interlocking intramedullary nail: Standard of care device for tibia fracture repair; Randomized Treatment - Nail
|
Randomized Treatment - Plate
n=27 Participants
Randomized Treatment - Plate
locking periarticular plate: Standard of care device for tibia fracture repair; Randomized Treatment - Plate
|
|---|---|---|
|
Number of Participants With Fracture Nonunions
|
4 Participants
|
5 Participants
|
SECONDARY outcome
Timeframe: 6 monthsA superficial infection is an infection that occurs at the wound only. Participants are monitored during clinical exams throughout the 12 month follow up appointments and medical records are reviewed.
Outcome measures
| Measure |
Randomized Treatment - Nail
n=43 Participants
Randomized Treatment - Nail
reamed, interlocking intramedullary nail: Standard of care device for tibia fracture repair; Randomized Treatment - Nail
|
Randomized Treatment - Plate
n=38 Participants
Randomized Treatment - Plate
locking periarticular plate: Standard of care device for tibia fracture repair; Randomized Treatment - Plate
|
|---|---|---|
|
Number of Participants With Superficial Infections
|
0 Participants
|
2 Participants
|
SECONDARY outcome
Timeframe: 6 monthsA deep infection is an infection occurring at the site of the nail or plate. Participants are monitored during clinical exams throughout the 12 month follow up appointments and medical records are reviewed.
Outcome measures
| Measure |
Randomized Treatment - Nail
n=43 Participants
Randomized Treatment - Nail
reamed, interlocking intramedullary nail: Standard of care device for tibia fracture repair; Randomized Treatment - Nail
|
Randomized Treatment - Plate
n=38 Participants
Randomized Treatment - Plate
locking periarticular plate: Standard of care device for tibia fracture repair; Randomized Treatment - Plate
|
|---|---|---|
|
Number of Participants With Deep Infections
|
3 Participants
|
1 Participants
|
SECONDARY outcome
Timeframe: 6 monthsCompartment syndrome is a painful condition that occurs when pressure within the muscles builds to dangerous levels. Participants are monitored during clinical exams throughout the 12 month follow up appointments and medical records are reviewed.
Outcome measures
| Measure |
Randomized Treatment - Nail
n=43 Participants
Randomized Treatment - Nail
reamed, interlocking intramedullary nail: Standard of care device for tibia fracture repair; Randomized Treatment - Nail
|
Randomized Treatment - Plate
n=38 Participants
Randomized Treatment - Plate
locking periarticular plate: Standard of care device for tibia fracture repair; Randomized Treatment - Plate
|
|---|---|---|
|
Number of Participants With Compartment Syndrome
|
1 Participants
|
0 Participants
|
SECONDARY outcome
Timeframe: 12 monthsMalunion is when a broken bone heals in an abnormal position. In this case, more than a 5 degree angle varus (curving into) or valgus (curving away). This is determined by a review of the participants' medical records and x-rays.
Outcome measures
| Measure |
Randomized Treatment - Nail
n=22 Participants
Randomized Treatment - Nail
reamed, interlocking intramedullary nail: Standard of care device for tibia fracture repair; Randomized Treatment - Nail
|
Randomized Treatment - Plate
n=27 Participants
Randomized Treatment - Plate
locking periarticular plate: Standard of care device for tibia fracture repair; Randomized Treatment - Plate
|
|---|---|---|
|
Number of Participants With Malunion (>5 Degrees Varus/Valgus)
|
3 Participants
|
3 Participants
|
Adverse Events
Randomized Treatment - Nail
Randomized Treatment - Plate
Serious adverse events
| Measure |
Randomized Treatment - Nail
n=52 participants at risk
Randomized Treatment - Nail
reamed, interlocking intramedullary nail: Standard of care device for tibia fracture repair; Randomized Treatment - Nail
|
Randomized Treatment - Plate
n=47 participants at risk
Randomized Treatment - Plate
locking periarticular plate: Standard of care device for tibia fracture repair; Randomized Treatment - Plate
|
|---|---|---|
|
Surgical and medical procedures
Patient fall
|
1.9%
1/52 • Number of events 1 • 6 years
Adverse event information was collected during clinical followup appointments through questionnaires/surveys.
|
0.00%
0/47 • 6 years
Adverse event information was collected during clinical followup appointments through questionnaires/surveys.
|
|
Surgical and medical procedures
Fracture
|
1.9%
1/52 • Number of events 1 • 6 years
Adverse event information was collected during clinical followup appointments through questionnaires/surveys.
|
2.1%
1/47 • Number of events 1 • 6 years
Adverse event information was collected during clinical followup appointments through questionnaires/surveys.
|
|
Musculoskeletal and connective tissue disorders
Osteoporosis
|
1.9%
1/52 • Number of events 1 • 6 years
Adverse event information was collected during clinical followup appointments through questionnaires/surveys.
|
0.00%
0/47 • 6 years
Adverse event information was collected during clinical followup appointments through questionnaires/surveys.
|
|
Respiratory, thoracic and mediastinal disorders
Pneumonia
|
0.00%
0/52 • 6 years
Adverse event information was collected during clinical followup appointments through questionnaires/surveys.
|
2.1%
1/47 • Number of events 1 • 6 years
Adverse event information was collected during clinical followup appointments through questionnaires/surveys.
|
|
Cardiac disorders
Death
|
1.9%
1/52 • Number of events 1 • 6 years
Adverse event information was collected during clinical followup appointments through questionnaires/surveys.
|
0.00%
0/47 • 6 years
Adverse event information was collected during clinical followup appointments through questionnaires/surveys.
|
Other adverse events
| Measure |
Randomized Treatment - Nail
n=52 participants at risk
Randomized Treatment - Nail
reamed, interlocking intramedullary nail: Standard of care device for tibia fracture repair; Randomized Treatment - Nail
|
Randomized Treatment - Plate
n=47 participants at risk
Randomized Treatment - Plate
locking periarticular plate: Standard of care device for tibia fracture repair; Randomized Treatment - Plate
|
|---|---|---|
|
Surgical and medical procedures
Painful Implant
|
3.8%
2/52 • Number of events 2 • 6 years
Adverse event information was collected during clinical followup appointments through questionnaires/surveys.
|
0.00%
0/47 • 6 years
Adverse event information was collected during clinical followup appointments through questionnaires/surveys.
|
|
Infections and infestations
Infection
|
5.8%
3/52 • Number of events 3 • 6 years
Adverse event information was collected during clinical followup appointments through questionnaires/surveys.
|
6.4%
3/47 • Number of events 3 • 6 years
Adverse event information was collected during clinical followup appointments through questionnaires/surveys.
|
|
Surgical and medical procedures
Nonunion
|
7.7%
4/52 • Number of events 4 • 6 years
Adverse event information was collected during clinical followup appointments through questionnaires/surveys.
|
10.6%
5/47 • Number of events 5 • 6 years
Adverse event information was collected during clinical followup appointments through questionnaires/surveys.
|
|
Surgical and medical procedures
Malunion
|
5.8%
3/52 • Number of events 3 • 6 years
Adverse event information was collected during clinical followup appointments through questionnaires/surveys.
|
6.4%
3/47 • Number of events 3 • 6 years
Adverse event information was collected during clinical followup appointments through questionnaires/surveys.
|
|
Surgical and medical procedures
Wound Breakdown Right Proximal Tibia Surgical Site
|
3.8%
2/52 • Number of events 2 • 6 years
Adverse event information was collected during clinical followup appointments through questionnaires/surveys.
|
0.00%
0/47 • 6 years
Adverse event information was collected during clinical followup appointments through questionnaires/surveys.
|
|
Surgical and medical procedures
Anterior compartment not functional
|
1.9%
1/52 • Number of events 1 • 6 years
Adverse event information was collected during clinical followup appointments through questionnaires/surveys.
|
0.00%
0/47 • 6 years
Adverse event information was collected during clinical followup appointments through questionnaires/surveys.
|
|
Surgical and medical procedures
Delayed Union
|
1.9%
1/52 • Number of events 1 • 6 years
Adverse event information was collected during clinical followup appointments through questionnaires/surveys.
|
0.00%
0/47 • 6 years
Adverse event information was collected during clinical followup appointments through questionnaires/surveys.
|
|
Surgical and medical procedures
Peripheral Nerve Injury
|
0.00%
0/52 • 6 years
Adverse event information was collected during clinical followup appointments through questionnaires/surveys.
|
4.3%
2/47 • Number of events 2 • 6 years
Adverse event information was collected during clinical followup appointments through questionnaires/surveys.
|
|
Surgical and medical procedures
DVT
|
1.9%
1/52 • Number of events 1 • 6 years
Adverse event information was collected during clinical followup appointments through questionnaires/surveys.
|
0.00%
0/47 • 6 years
Adverse event information was collected during clinical followup appointments through questionnaires/surveys.
|
Additional Information
Results disclosure agreements
- Principal investigator is a sponsor employee
- Publication restrictions are in place