Short Term Effects of FX Dialysers on QOL and Inflammation
NCT ID: NCT00291603
Last Updated: 2007-04-25
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
PHASE4
50 participants
INTERVENTIONAL
2006-02-28
2006-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
The new hollow fibre FX-class of dialysers (Fresenius Medical Care, Bad Homburg, Germany) features a number of technological improvements that may benefit the patient. This includes the use of the advanced high-flux polysulfone membrane, Helixone®, which has an extremely high endotoxin retaining capability. Theoretically leading to reduced systemic inflammation in the patient, which is an important factor for morbidity and mortality with dialysis.
The dialysis membrane is the first to be manufactured using membrane-spinning procedures (nano-controlled spinning technology) that enables the membrane to be modulated at the nano-scale level. The resultant membrane is able to extremely efficiently remove middle molecules, along with minimal loss of albumin.
These features may lead to improved patient outcomes, including reduced systemic inflammation and improved quality of life.
Aims:
1. To assess the short-term effects of the FX-class Dialyser on quality of life in stable haemodialysis patients
2. To assess the short-term effects of the FX-class Dialyser on inflammatory markers in stable haemodialysis patients.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Inclusion criteria -
1. Age \>18years
2. Able to provide informed consent
3. On haemodialysis for 3 months
Exclusion criteria -
1. Active inflammatory, infective or neoplastic process within the last 1 month
2. Active major psychiatric condition
3. Currently on haemodiafiltration as haemodialysis modality
Design This study will involve an unblinded, cross-over design, with patients being randomised upon entry into one of 2 groups. The 2 groups will be - 1. HF80 dialyser (this is the best of the currently used dialysers and therefore no participant will require a reduction in their dialysis during this trial); and 2. FX dialyser. Patients will have baseline tests performed prior to intervention and then repeated after 3 months. At 3 months, patients will then cross-over into the other group and tests repeated after a further 6 months.
Due to the nature of the intervention, blinding will not be practical. The cross-over design will allow maximum power for this fixed and relatively small dialysis population (\~50 patients).
Independent variables -
1. Dialysis prescription on enrolment
a. Including dialyser type (biocompatibility)
2. Adequacy of dialysis
1. Urea reduction ratio
2. Kt/V
3. Anaemia
1. Including iron studies
2. Including erythropoietin usage
4. Calcium phosphate balance
a. Including Parathyroid hormone levels
5. Serum albumin
Outcome markers -
1. Quality of Life (i) KD-QOL - this is a standardised quality of life questionnaire designed and validated for dialysis patients, that will be readily comparable to other studies.
(ii) Feeling thermometer
2. Inflammatory markers (i) High sensitivity c-reactive protein (ii) IL-6 (iii) White cell count.
Statistical analysis:
Quality of life measures and inflammatory markers will be analysed using paired t-test after normality demonstrated. Simple and multiple linear regression analysis will then be performed to examine associations between independent variables with changes in the outcome variables. STATA 8.2 will be used to assist with the analysis
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
CROSSOVER
TREATMENT
NONE
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
FX-class of dialyser
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Able to provide informed consent
3. On haemodialysis for 3 months
Exclusion Criteria
2. Active major psychiatric condition
3. Currently on haemodiafiltration as haemodialysis modality
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Sir Charles Gairdner Hospital
OTHER
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Neil C Boudville, MD
Role: PRINCIPAL_INVESTIGATOR
The University of Western Australia
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Joondalup Health Campus Satellite Dialysis Unit
Perth, Western Australia, Australia
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
2005-192
Identifier Type: -
Identifier Source: org_study_id