Markers in Exhaled Breath Condensate in Obstructive Sleep Apnoea (OSA) Patients

NCT ID: NCT00287638

Last Updated: 2010-01-22

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

60 participants

Study Classification

INTERVENTIONAL

Study Start Date

2006-01-31

Study Completion Date

2010-01-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Patients with obstructive sleep apnoea (OSA) have repetitive episodes of partial or complete upper airway obstruction during sleep. This leads to sleep fragmentation and symptoms like excessive daytime sleepiness and impaired psychosocial well-being. More evidence now suggested OSA is associated with cardiovascular diseases like hypertension, myocardial infarction, pulmonary hypertension and stroke.

The upper airway structure and function are altered in OSA. Some studies suggested that an increase in the levels of systemic biomarkers of inflammation and oxidative stress in patients with OSA. So far, there is only very limited data on non-invasive monitoring of inflammation involved in the upper airway of OSA patients. The inflammatory mechanisms involved in the upper airway may give some insights to the systemic effect, like cardiovascular complications, of OSA.

Measurement of the constituents of exhaled breath and exhaled breath condensate (EBC) is a non-invasive method to assess the degree of inflammation of the airway. Exhaled nitric oxide (eNO) can be measured with the subject exhaling to a mouthpiece connected to a machine measuring real-time eNO level. With the subject exhaling to a cooling unit, EBC can be collected as liquid is formed as a result of condensation.

This study will assess the eNO in exhaled breath, oxidative stress marker (8-isoprostane) and cellular inflammatory markers (eotaxin, monocyted derived chemokine, growth related oncogene- alpha, monocyte chemoattractant protein-1) in the EBC and blood of OSA patients before and after 1 night and 3 months of continuous positive airway pressure treatment.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Measurement of exhaled Nitric Oxide and collection of exhaled breath condensate and peripheral blood. This will be done 2 to 4 times(on admission,the morning after sleep study,immediately after CPAP titration, after CPAP use for 3 months). Each time eNO will be measured first, followed by EBC collection.

For the tests in the morning, patients will be asked to postpone his/her breakfast until after the test which will take less than half an hour.

OSA is defined as patients having a respiratory disturbance index of ≥5/hr.

Measurement of Exhaled Nitric Oxide:

eNO will be measured using a Sievers 280i chemiluminescence analyser (Sievers Instruments, Boulder, CO, USA) sensitive to NO from 1 ppb to 200 ppm and with a resolution of 1 ppb and accuracy of 1 ppb designed for online recording. The eNO measurement will be performed according to ATS standards. Briefly, subjects should remain seated without nose clip during the procedure, with 2-minute rest between eNO measurements. The eNO will be measured online at an expiratory flow rate of 50 ml/sec, a dead space of 10 ml and 2-second plateau duration. Repeated exhalations are performed until three NO plateau values agree at the 10% level or two agree at the 5% level. The mean NO value will then be recorded.

Collection of Exhaled Breath Condensate:

EBC will be collected using the ECoscreen (Jaeger, Germany) according to manufacturer instructions. After rinsing their mouth, the recruited subjects will breathe tidally through a mouthpiece that is connected through a unique one-way valve into a cooled collection tube where vapours, aerosols and moisture in the breath condense along the walls of the tube. The one-way valve is then used as a plunger that collects droplets stuck to the inside wall and holds the sample near the top of the tube. The device inherently prevents salivary contamination as shown by the absence of salivary amylase in EBC. On average, this device will be able to collect 300 microL per minute of EBC for an adult. Each subject will be asked to breathe through the collection kit for 5 minutes, which should be sufficiently long to yield 1 ml of condensate for inflammatory marker analysis. EBC will be stored immediately at -70oC until analysis for inflammatory markers.

Measurement of 8 isoprostane, GRO alpha, MCP1, eotaxin and MDC levels in exhaled breath condensate:

EBC stored at -70oC will be analysed for 8-isoprostane, GROalpha, MCP1, eotaxin and MDC levels concentrations in batches. We will use 96-well polystyrene microplates coated with murine monoclonal antibodies against human 8 isoprostane, GRO alpha, MCP1, eotaxin and MDC levels. The levels of these markers in EBC will be measured in duplicates by sandwich enzyme immunoassay (R \& D Systems, Minneapolis, MN, USA) according to instructions provided by the manufacturer.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Obstructive Sleep Apnea

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NON_RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

1

CPAP

Group Type ACTIVE_COMPARATOR

CPAP

Intervention Type DEVICE

Continuous positive pressure device with a time clock

2

no CPAP

Group Type PLACEBO_COMPARATOR

placebo

Intervention Type DEVICE

no CPAP

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

CPAP

Continuous positive pressure device with a time clock

Intervention Type DEVICE

placebo

no CPAP

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Patients will be recruited upon admission for sleep study under the Division of Respiratory Medicine, Prince of Wales Hospital.
* Patients who are aged 18 to 60 will be recruited.

Exclusion Criteria

* Known history of respiratory disease that will affect inflammatory markers in EBC like asthma, chronic obstructive pulmonary disease and bronchiectasis.
* Upper or lower respiratory tract infection within 6 weeks from the study.
* Current smokers, or ex-smoker who quitted for less than a year.
* Pregnant subjects.
* Any form of malignancies or serious medical illness that will affect the survival of the subject significantly in 1 year period.
Minimum Eligible Age

18 Years

Maximum Eligible Age

60 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Chinese University of Hong Kong

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

The Chinese University of Hong Kong

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Fanny WS Ko, MBChB

Role: PRINCIPAL_INVESTIGATOR

CUHK

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Prince of Wales Hospital

Shatin, N.T., Hong Kong

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Hong Kong

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

Resp/ko/2006/002

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Psychological Aspects in OSA
NCT06292325 COMPLETED