Trial Outcomes & Findings for Chest Wall Oscillation for Asthma and COPD Exacerbations Trial (COAT) (NCT NCT00181285)

NCT ID: NCT00181285

Last Updated: 2018-08-08

Results Overview

Patient adherence to therapy after four treatments.

Recruitment status

COMPLETED

Study phase

NA

Target enrollment

52 participants

Primary outcome timeframe

After four treatments of 15 minutes each

Results posted on

2018-08-08

Participant Flow

Participant milestones

Participant milestones
Measure
Sham High Frequency Chest Wall Oscillation
Sham high frequency chest wall oscillation. High Frequency Chest Wall Oscillator: High velocity, low amplitude oscillatory airflow applied through a pneumatic vest worn over the thorax
Active High Frequency Chest Wall Oscillation
High frequency chest wall oscillation High Frequency Chest Wall Oscillator: High velocity, low amplitude oscillatory airflow applied through a pneumatic vest worn over the thorax
Overall Study
STARTED
27
25
Overall Study
COMPLETED
27
25
Overall Study
NOT COMPLETED
0
0

Reasons for withdrawal

Withdrawal data not reported

Baseline Characteristics

Sex/Gender was not collected from any participant.

Baseline characteristics by cohort

Baseline characteristics by cohort
Measure
Sham High Frequency Chest Wall Oscillation
n=27 Participants
Sham high frequency chest wall oscillation High Frequency Chest Wall Oscillator: High velocity, low amplitude oscillatory airflow applied through a pneumatic vest worn over the thorax
Active High Frequency Chest Wall Oscillation
n=25 Participants
High frequency chest wall oscillation High Frequency Chest Wall Oscillator: High velocity, low amplitude oscillatory airflow applied through a pneumatic vest worn over the thorax
Total
n=52 Participants
Total of all reporting groups
Age, Continuous
50.4 years
n=27 Participants
46.5 years
n=25 Participants
48.5 years
n=52 Participants
Sex: Female, Male
Female
0 Participants
Sex/Gender was not collected from any participant.
Sex: Female, Male
Male
0 Participants
Sex/Gender was not collected from any participant.
Race and Ethnicity Not Collected
0 Participants
Race and Ethnicity were not collected from any participant.

PRIMARY outcome

Timeframe: After four treatments of 15 minutes each

Patient adherence to therapy after four treatments.

Outcome measures

Outcome measures
Measure
Sham High Frequency Chest Wall Oscillation
n=27 Participants
Sham high frequency chest wall oscillation High Frequency Chest Wall Oscillator: High velocity, low amplitude oscillatory airflow applied through a pneumatic vest worn over the thorax
Active High Frequency Chest Wall Oscillation
n=25 Participants
Active high frequency chest wall oscillation High Frequency Chest Wall Oscillator: High velocity, low amplitude oscillatory airflow applied through a pneumatic vest worn over the thorax
Patient Adherence to High Frequency Chest Wall Oscillation
93 Percent of 60 minutes prescribed
Standard Deviation 18.7
91 Percent of 60 minutes prescribed
Standard Deviation 21.1

PRIMARY outcome

Timeframe: After four treatments of 15 minutes each

Population: 1 participant in the Sham group and 1 participant in the Active group had missing data for the question regarding the convenience of the pneumatic vest, therefore these participants were not included in the number analyzed for the outcome measure data table below.

The study vest was convenient to use.

Outcome measures

Outcome measures
Measure
Sham High Frequency Chest Wall Oscillation
n=26 Participants
Sham high frequency chest wall oscillation High Frequency Chest Wall Oscillator: High velocity, low amplitude oscillatory airflow applied through a pneumatic vest worn over the thorax
Active High Frequency Chest Wall Oscillation
n=24 Participants
Active high frequency chest wall oscillation High Frequency Chest Wall Oscillator: High velocity, low amplitude oscillatory airflow applied through a pneumatic vest worn over the thorax
Number of Participants Who Considered the Pneumatic Vest Convenient to Use
24 Participants
19 Participants

Adverse Events

Sham High Frequency Chest Wall Oscillation

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Active High Frequency Chest Wall Oscillation

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Serious adverse events

Adverse event data not reported

Other adverse events

Adverse event data not reported