Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
10 participants
OBSERVATIONAL
1997-09-30
2000-08-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Surgery is currently the only treatment for cataracts. Many laboratories, however, are researching drugs to reverse, delay or prevent cataract formation. Anti-cataract drugs presumably would be most effective given early in the course of disease. When clinical trials of these drugs are begun, dependable and standardized methods for documenting and monitoring lens opacities will be needed to test their effectiveness. The QLS was designed to detect the earliest molecular changes in cataract development. This study will evaluate the usefulness and reliability of this instrument in measuring these changes.
Normal volunteers and patients with cataracts in this study will have a standard eye examination, including a vision test and eye pressure measurement. The pupils will be dilated for QLS testing and for examination of the retina. Photographs of the retina may be taken. The QLS test uses a very dim laser light similar to that used to scan grocery items in the supermarket. The laser beam is projected into the lens of the eye, and the scattered light is collected and analyzed to determine normal and abnormal molecular interactions in the lens. Two measurements will be done for each eye. The test will be repeated in 6 months to determine reproducibility of the system.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Dynamic Light Scattering Device (DLS) Study of Age-Related Changes in the Lens and Cataracts
NCT00007215
Pilot Study: Dynamic Light Scattering Device for Studying Early Changes in Cataract
NCT00067483
Dynamic Light Scattering for Studying Lens Aging and Cataract Formation
NCT00081991
Dynamic Light Scattering to Study Crystalline Proteins in Young Normal Lenses
NCT00304967
Cataract Surgery to Obtain Human Lens Material for the Study of Nuclear Cataracts
NCT00001613
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Three subjects who are normal volunteers below age 40 and three subjects who are normal volunteers above age 40 will be recruited. These normal volunteers should have clear lenses with LOCS II clinical score for nuclear opalescence of 0.5 or less.
In addition, 3 subjects who have early nuclear cataract (LOCS II/Nuclear opalescence -2) will also be recruited for the study.
QLS data will be obtained on each eye of the normal and cataractous subjects in the nuclear region.
No patients who have uveitis, glaucoma and who are thought to be at risk for an adverse reaction to pupil dilation, or have a history of allergic reaction to one of the dilating agents that will be used.
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
National Eye Institute (NEI)
NIH
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
National Eye Institute (NEI)
Bethesda, Maryland, United States
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Benedek GB, Chylack LT Jr, Libondi T, Magnante P, Pennett M. Quantitative detection of the molecular changes associated with early cataractogenesis in the living human lens using quasielastic light scattering. Curr Eye Res. 1987 Dec;6(12):1421-32. doi: 10.3109/02713688709044506.
Bursell SE, Baker RS, Weiss JN, Haughton JF, Rand LI. Clinical photon correlation spectroscopy evaluation of human diabetic lenses. Exp Eye Res. 1989 Aug;49(2):241-58. doi: 10.1016/0014-4835(89)90094-8.
Datiles M, Podgor M, Edwards P. Reproducibility of the Early Cataract Detector (Kowa ECD 2000). Ophthalmic Surg. 1988 Sep;19(9):664-6.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
97-EI-0183
Identifier Type: -
Identifier Source: secondary_id
970183
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.